Baysaver Technologies
Quick Quote

ENGINEERs

Easy Installation

The BaySaver Technologies’ BaySeparator is installed as part of the storm drain.  To begin, grout the BaySeparator unit and the system inlet pipe into the primary manhole.  Alternatively, use a watertight seal where local regulations specify.

The parallel pipes entering and leaving the storage manhole require watertight connections – these are made by using standard boots or other seals.  Flexible watertight couplers join BaySeparator to the parallel inlet and outlet pipes from the storage manhole.  These flexible seals prevent system failure in the event of differential settling between the two concrete structures.  Cover the pipes with gravel or any type of flowable fill.  Complete your final backfill and the BaySeparator is ready to start operation.